NIST SP 800-171 Rev. 2 Physical Protection requirements: objectives, evidence, and scope

NIST SP 800-171 Rev. 2 Physical Protection requirements: objectives, evidence, and scope

Map NIST SP 800-171 Rev. 2 physical protection requirements to assessment objectives, evidence prompts, and system-boundary questions.

Deep Fathom Last verified

Physical Protection covers access to systems and their operating areas, facility monitoring, visitors, access records, physical-access devices, and alternate work sites. The six requirements in NIST SP 800-171 Revision 2 map to 16 objectives in the June 2018 NIST SP 800-171A guide. Review the places where CUI work happens, not just the main office entrance. Visitor escorts, badge or key custody, and safeguards at a home work site answer different requirements. A badge system doesn’t by itself establish that visitors are monitored or that CUI is protected at an alternate location.

Physical Protection requirement map

NIST SP 800-171 Revision 2 places 6 requirements in the Physical Protection family. NIST SP 800-171A expresses 16 assessment-objective statements for those requirements. The source text is retained here because the family name alone does not resolve a system-boundary or evidence question.

This series quotes historical NIST SP 800-171 Revision 2 and its June 2018 assessment guide. Both publications are withdrawn. Check the edition and requirements incorporated by the applicable contract before using this historical map.

RequirementNIST SP 800-171 Rev. 2 requirement textNIST SP 800-171A assessment objectives
3.10.1Limit physical access to organizational systems, equipment, and the respective operating environments to authorized individuals.3.10.1[a] authorized individuals allowed physical access are identified.
3.10.1[b] physical access to organizational systems is limited to authorized individuals.
3.10.1[c] physical access to equipment is limited to authorized individuals.
3.10.1[d] physical access to operating environments is limited to authorized individuals.
3.10.2Protect and monitor the physical facility and support infrastructure for organizational systems.3.10.2[a] the physical facility where organizational systems reside is protected.
3.10.2[b] the support infrastructure for organizational systems is protected.
3.10.2[c] the physical facility where organizational systems reside is monitored.
3.10.2[d] the support infrastructure for organizational systems is monitored.
3.10.3Escort visitors and monitor visitor activity.3.10.3[a] visitors are escorted.
3.10.3[b] visitor activity is monitored.
3.10.4Maintain audit logs of physical access.3.10.4 audit logs of physical access are maintained.
3.10.5Control and manage physical access devices.3.10.5[a] physical access devices are identified.
3.10.5[b] physical access devices are controlled.
3.10.5[c] physical access devices are managed.
3.10.6Enforce safeguarding measures for CUI at alternate work sites.3.10.6[a] safeguarding measures for CUI are defined for alternate work sites.
3.10.6[b] safeguarding measures for CUI are enforced for alternate work sites.

Evidence and scoping review

NIST SP 800-171A presents potential assessment methods and objects under Examine, Interview, and Test. The following evidence prompts are Deep Fathom editorial planning examples. They do not guarantee assessor acceptance, prescribe one tool, or expand the NIST requirements.

Requirement objectivesEditorial evidence exampleScoping question
3.10.1Authorized-person lists, facility access controls, and sampled access records.Who may physically reach the systems, equipment, and operating areas within the boundary?
3.10.2Facility protection arrangements, monitoring coverage, and review records.Which facilities and supporting infrastructure require protection and monitoring, including shared locations?
3.10.3Visitor sign-in records, escort assignments, and a sampled visitor walkthrough.Where may visitors go, who escorts them, and how is their activity monitored?
3.10.4Physical-access log records and the procedure for retaining and reviewing them.Which entrances or access points generate records, and can a sampled entry be traced?
3.10.5Badge, key, and other access-device inventories, issuance records, and revocation actions.Who holds each physical-access device, and what happens when one is lost or its holder leaves?
3.10.6Alternate-work-site safeguards and a review of a representative remote work location.How is CUI protected at home or other alternate sites, including paper records, screens, and equipment?

Apply the Physical Protection family in a concrete review

Requirement 3.10.6 applies safeguarding measures at alternate work sites, and the Rev. 2 discussion names private employee residences as one possible alternate site. The same family separately requires visitor escort and monitoring in 3.10.3 and control and management of physical-access devices in 3.10.5. It does not make a home office automatically prohibited or automatically approved.

Editorial example: for a residence where CUI activity occurs, record the activity, the people with physical access, the visitor and device-control arrangement, and the safeguards selected for that site. A badge, lock, or visitor log is evidence only when it supports the applicable mapped objective.

A practical review starts with the CUI boundary guide, then uses the NIST 800-171 Rev. 2 and Rev. 3 comparison, the CMMC compliance checklist, CMMC for subcontractors. The requirement-to-objective map and the requirement-specific evidence rows above remain the review anchors.

References

References · 3 official sources
SourceWhat it supportsType
NIST SP 800-171 Revision 2Physical Protection requirement text and the 14-family structureStandard
NIST SP 800-171ACorresponding assessment-objective statements and potential assessment methodsStandard
NARA CUI FAQContract-directed CUI handling contextGuidance